Q&A: Installing 20-Amp Breakers

1 MIN READ
Q. In a residential rewiring job, I am removing the existing conductors from steel flex conduit and installing new #12 solid wire, pulled through the flex conduit. Can I convert all of the existing 15-amp breakers to 20-amp breakers?

A.Master electrician Rex Cauldwell responds: Yes, you can. Since you have installed 12-gauge wire, and since the breakers are there to protect the wiring, there is no reason you can’t install 20-amp breakers — as long as you don’t put more than three conductors in the conduit. If you install more than three conductors in the conduit, you would have to start to derate the conductors.

Register to download and view this article

Get your copy

About the Author

Rex Cauldwell

Rex Cauldwell is a master electrician and owner of Little Mountain Plumbing and Electric in Copper Hill, Va.